Key Features

Hydratron Double Acting Air Driven Gas Boosters offer many desirable features:

  • Ability to stall at a predetermined pressure and hold this fixed pressure without consuming power or generating heat
  • No risk of flame or spark
  • Infinitely variable speed/output flowrate control
  • Infinitely variable output pressure control
  • Easy to apply automatic controls
  • Standard models are suitable for Air, Nitrogen & Helium. Design options are available for more hazardous gases
  • No limit or adverse effects in continuous stop/start applications
  • Proven reliability, easy to maintain and robust

Specification

  • Air filter, lubricator, pressure regulator, pressure gauge & speed control valve
  • 6” (150mm) diameter panel mounted outlet pressure gauge
  • Pressure release valve
  • All interconnecting pipework & fittings
  • Robust Stainless Steel Frame as standard

Options

  • Offshore specification available
  • Stroke Counter
  • Outlet Pressure Isolation
  • On board chart recorder
  • Wheels / castors 

Performance Data

ModelMax Output Pressure
@ 100 psi (7bar) Air Drive
Displacement/
Stroke
Max Compression Ratio Supply Pressure to Achieve Max Output Pressure  Actual Output Pressure (Stall Condition)
PsiBarCu Inscc'sPsiBar
GBD33570039315.6255.715:1240016633PA+PS
GBD6690006218.0131.115:1240016666PA+PS
GBD118142009794.573.815:12400166118PA+PS
GBD1862100014483.049.215:12400166186PA+PS
Model NumberInlet PressureOutlet PressureFlow
PsiBarPsiBarSCFMN Ltr/min
GBD33100069200013831.30886
GBD662000138400027631.50891
GBD1182000138600041420.40577
GBD18625001721000069016.40464